Test beam performance of CDF plug upgrade EM calorimeter

PDF Version Also Available for Download.

Description

CDF Plug Upgrade(tile-fiber) EM Calorimeter performed resolution of 15%/{radical}E{circle_plus}0.7% with non-linearity less than 1% in a energy range of 5-180 GeV at Fermilab Test Beam. Transverse uniformity of inside-tower-response of the EM Calorimeter was 2.2% with 56 GeV positron, which was reduced to 1.0% with response map correction. We observed 300 photo electron/GeV in the EM Calorimeter. Ratios of EM Calorimeter response to positron beam to that to {sup 137}Cs Source was stable within 1% in the period of 8 months.

Physical Description

8 p.; Other: FDE: POSTSCRIPT; PL:

Creation Information

Fukui, Y. & Group, CDF Upgrade January 1, 1998.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Authors

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

CDF Plug Upgrade(tile-fiber) EM Calorimeter performed resolution of 15%/{radical}E{circle_plus}0.7% with non-linearity less than 1% in a energy range of 5-180 GeV at Fermilab Test Beam. Transverse uniformity of inside-tower-response of the EM Calorimeter was 2.2% with 56 GeV positron, which was reduced to 1.0% with response map correction. We observed 300 photo electron/GeV in the EM Calorimeter. Ratios of EM Calorimeter response to positron beam to that to {sup 137}Cs Source was stable within 1% in the period of 8 months.

Physical Description

8 p.; Other: FDE: POSTSCRIPT; PL:

Notes

INIS; OSTI as DE98051891

Source

  • Conference on scintillating and fiber detectors (SCIFI 97), South Bend, IN (United States), 2-6 Nov 1997

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE98051891
  • Report No.: FNAL/C--98/032-E
  • Report No.: CONF-9711110--
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 572842
  • Archival Resource Key: ark:/67531/metadc698047

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • January 1, 1998

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • April 1, 2016, 5:05 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Fukui, Y. & Group, CDF Upgrade. Test beam performance of CDF plug upgrade EM calorimeter, article, January 1, 1998; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc698047/: accessed August 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.