45-Day safety screen results for Tank 241-B-112, auger samples 95-AUG-014 and 95-AUG-015

PDF Version Also Available for Download.

Description

Two auger samples from Tank 241-B-112 (B-112) were received in the 222-S Laboratories and underwent safety screening analyses, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. All results for all analyses (DSC, TGA, and total alpha) were within the safety screening notification limits specified in the Tank Characterization Plan (TCP). No notification nor secondary analyses were required. Tank B-112 is not part of any of the four Watch Lists.

Physical Description

34 p.

Creation Information

Conner, J.M. May 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Two auger samples from Tank 241-B-112 (B-112) were received in the 222-S Laboratories and underwent safety screening analyses, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. All results for all analyses (DSC, TGA, and total alpha) were within the safety screening notification limits specified in the Tank Characterization Plan (TCP). No notification nor secondary analyses were required. Tank B-112 is not part of any of the four Watch Lists.

Physical Description

34 p.

Notes

INIS; OSTI as DE95011653

Source

  • Other Information: PBD: 1 May 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95011653
  • Report No.: WHC-SD-WM-DP--105
  • Grant Number: AC06-87RL10930
  • DOI: 10.2172/61105 | External Link
  • Office of Scientific & Technical Information Report Number: 61105
  • Archival Resource Key: ark:/67531/metadc695886

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • May 1, 1995

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • Feb. 8, 2016, 12:49 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Conner, J.M. 45-Day safety screen results for Tank 241-B-112, auger samples 95-AUG-014 and 95-AUG-015, report, May 1, 1995; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc695886/: accessed August 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.