Thermal stability of LX-09 chemical reactivity testing. Final report

PDF Version Also Available for Download.

Description

Several CRT tests were performed with LX-09 using sample containers obtained from LLL. These containers were used to help eliminate differences that were inherent in the design of the various sample containers used by the different laboratories. Initial experiments showed poor agreement in test data between LLL and Pantex containers until Pantex containers were fitted with different valves. Later experiments show no significant differences in test data between the two types of containers after the modification. Fillers of stainless steel (used in LLL containers) and of glass (used in Pantex containers) were interchanged with-out significant differences in results. Results of ... continued below

Physical Description

10 p.

Creation Information

Teter, A.C. September 1, 1971.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Mason & Hanger-Silas Mason Co.
    Publisher Info: Mason and Hanger-Silas Mason Co., Inc., Amarillo, TX (United States)
    Place of Publication: Amarillo, Texas

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Several CRT tests were performed with LX-09 using sample containers obtained from LLL. These containers were used to help eliminate differences that were inherent in the design of the various sample containers used by the different laboratories. Initial experiments showed poor agreement in test data between LLL and Pantex containers until Pantex containers were fitted with different valves. Later experiments show no significant differences in test data between the two types of containers after the modification. Fillers of stainless steel (used in LLL containers) and of glass (used in Pantex containers) were interchanged with-out significant differences in results. Results of tests with PBX 9404 and with LX-04-1 are included.

Physical Description

10 p.

Notes

OSTI as DE97008777

Source

  • Other Information: PBD: Sep 1971

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE97008777
  • Report No.: MHSMP--71-87W
  • Grant Number: AC04-91AL65030
  • DOI: 10.2172/525048 | External Link
  • Office of Scientific & Technical Information Report Number: 525048
  • Archival Resource Key: ark:/67531/metadc695680

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 1, 1971

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • May 4, 2016, 3:45 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 5

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Teter, A.C. Thermal stability of LX-09 chemical reactivity testing. Final report, report, September 1, 1971; Amarillo, Texas. (digital.library.unt.edu/ark:/67531/metadc695680/: accessed December 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.