Existing Housing - Much of the older multifamily housing stock in the United States includes units in structures with uninsulated masonry walls. Included in this stock are two- and three-story walk-up apartments, larger apartment complexes, and public housing (both high- rise and townhouse). This older multifamily housing has seen years of heavy use that may have left the plaster wall marred or damaged. Long- term building settlement or movement may have cracked the plaster, sometimes severely. Moisture from invented kitchens and baths may have caused condensation on uninsulated exterior walls. At best this condensation has left stains on the paint ...
continued below
Publisher Info:
Oak Ridge National Lab., TN (United States). Energy Div.
Place of Publication:
Tennessee
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this article.
Follow the links below to find similar items on the Digital Library.
Description
Existing Housing - Much of the older multifamily housing stock in the United States includes units in structures with uninsulated masonry walls. Included in this stock are two- and three-story walk-up apartments, larger apartment complexes, and public housing (both high- rise and townhouse). This older multifamily housing has seen years of heavy use that may have left the plaster wall marred or damaged. Long- term building settlement or movement may have cracked the plaster, sometimes severely. Moisture from invented kitchens and baths may have caused condensation on uninsulated exterior walls. At best this condensation has left stains on the paint or wallpaper. At worst it has supported mold and mildew growth, fouling the air and creating unhealthy living conditions. Deteriorating plaster and flaking paint also result from wet walls. The presence of flaking, lead-based paint in older (pre-1978) housing is a major public health concern. Children can suffer permanent mental handicaps and psychological disorders if they are subjected to elevated levels of lead, while adults can suffer hypertension and other maladies. Studies have found that, in some urban communities with older housing stocks, over 35% of children tested have elevated blood lead levels (Hastings, et al.: 1997). Nationally, nearly 22% of black, non-hispanic children living in pre-1946 housing were found to have elevated levels of lead in their blood (MWWR Article: February 21,1997). The deterioration of many of these walls is to the point that lead can freely enter the living space.
This article is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Wendt, Robert L. & Cavallo, James.Innovative Composite Wall System for Sheathing Masonry Walls,
article,
September 25, 1997;
Tennessee.
(digital.library.unt.edu/ark:/67531/metadc694974/:
accessed February 19, 2019),
University of North Texas Libraries, Digital Library, digital.library.unt.edu;
crediting UNT Libraries Government Documents Department.