Description

The SLC final focus system accommodates 29 fixed or adjustable collimators for machine protection and background reduction. By amplifying pulse to pulse orbit variations and by generating emittance growth, collimator wake fields may degrade the beam quality at the interaction point (IP). In the SLC final focus, collimator half apertures are larger than the bunch length, so that the standard collimator wake formula of Bane and Morton does not apply. Numerical wake field calculations for SLC parameters agree quite well with the high frequency impedance of a step out transition. Due to the nature of a final focus system, the ... continued below

Physical Description

6 p.

Creation Information

Zimmermann, F.; Bane, K.L.F. & Ng, C.K. June 1, 1996.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The SLC final focus system accommodates 29 fixed or adjustable collimators for machine protection and background reduction. By amplifying pulse to pulse orbit variations and by generating emittance growth, collimator wake fields may degrade the beam quality at the interaction point (IP). In the SLC final focus, collimator half apertures are larger than the bunch length, so that the standard collimator wake formula of Bane and Morton does not apply. Numerical wake field calculations for SLC parameters agree quite well with the high frequency impedance of a step out transition. Due to the nature of a final focus system, the wake field kicks from all collimators add coherently, and the overall impact on luminosity can be significant. This paper suggests that collimator wake fields in the final focus provide a possible explanation for the 30% discrepancy between expected and measured luminosity in the 1994/95 SLC run.

Physical Description

6 p.

Notes

OSTI as DE97009075

Source

  • EPAC `96: 5. European particle accelerator conference, Barcelona (Spain), 10-14 Jun 1996

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE97009075
  • Report No.: SLAC-PUB--7137
  • Report No.: CONF-960621--
  • Grant Number: AC03-76SF00515
  • Office of Scientific & Technical Information Report Number: 626415
  • Archival Resource Key: ark:/67531/metadc694041

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • June 1, 1996

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • Aug. 9, 2016, 12:29 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Zimmermann, F.; Bane, K.L.F. & Ng, C.K. Collimator wake fields in the SLC final focus, article, June 1, 1996; California. (digital.library.unt.edu/ark:/67531/metadc694041/: accessed August 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.