Description

Cannon Boiler Works Inc. has been investigating a system for removing NOx from the exhaust gases of furnaces, gas turbines, chemical reactors, incinerators, and boilers. Computer simulations, bench-scale and pilot plant tests have proved that the system is capable of removing substantially all of the NOx from natural gas fired equipment exhaust streams. Originally designated as the Cannon NOx Digester, it has recently been renamed the Low Temperature Oxidation (LTO) System for NOx and SOx Reduction. The principal elements in the system are a fan, heat exchanger, oxidation chamber, spray chamber acting as a gas/liquid absorber, demister, an ozone generator, ... continued below

Physical Description

81 p.

Creation Information

Creator: Unknown. April 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Cannon Boiler Works Inc. has been investigating a system for removing NOx from the exhaust gases of furnaces, gas turbines, chemical reactors, incinerators, and boilers. Computer simulations, bench-scale and pilot plant tests have proved that the system is capable of removing substantially all of the NOx from natural gas fired equipment exhaust streams. Originally designated as the Cannon NOx Digester, it has recently been renamed the Low Temperature Oxidation (LTO) System for NOx and SOx Reduction. The principal elements in the system are a fan, heat exchanger, oxidation chamber, spray chamber acting as a gas/liquid absorber, demister, an ozone generator, liquid oxygen storage or dry air supply system for the ozonator, chemical storage and metering system for the caustic neutralizer, and a data acquisition and control system. Most of the ozone is consumed in converting NOx to N{sub 2}O{sub 5} which hydrates to nitric acid which is then scrubbed out of the gas as it passes through the absorber. CO also reacts with ozone to form CO{sub 2} which is subsequently scrubbed out with NaOH. A demonstration, planned for the Alta Dena Dairy located near Los Angeles and in violation of California`s air quality regulations for natural gas fired boilers, was started, delayed due to boiler modifications, and will be continued shortly with new funding. This paper describes the LTO process and presents results from the initial demonstration.

Physical Description

81 p.

Notes

OSTI as DE95009640

Source

  • Other Information: PBD: [1995]

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95009640
  • Report No.: DOE/PC/92161--1
  • Grant Number: FC22-92PC92161
  • DOI: 10.2172/52736 | External Link
  • Office of Scientific & Technical Information Report Number: 52736
  • Archival Resource Key: ark:/67531/metadc691911

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 1, 1995

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • Nov. 30, 2015, 6:32 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 6

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Closeout final report on a demonstration test and evaluation of the Cannon Low-NOx Digester System, report, April 1, 1995; United States. (digital.library.unt.edu/ark:/67531/metadc691911/: accessed September 21, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.