Description

Over the past 30 years, Monte Carlo simulation of photons interacting with matter has gradually improved to the extent that it now appears suitable for calibrating germanium detectors for counting efficiency in gamma-ray spectral analysis. The process is particularly useful because it can be applied for a variety of source shapes and spatial relations between source and detector by simply redefining the geometry, whereas calibration with radioactive standards requires a separate set of measurements for each source shape and location relative to the detector. Simulation accuracy was evaluated for two large (126% and 110%) and one medium-sized (20%) detectors with ... continued below

Physical Description

4 p.

Creation Information

Kamboj, Sunita & Kahn, B. August 1, 1997.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 12 times . More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

Over the past 30 years, Monte Carlo simulation of photons interacting with matter has gradually improved to the extent that it now appears suitable for calibrating germanium detectors for counting efficiency in gamma-ray spectral analysis. The process is particularly useful because it can be applied for a variety of source shapes and spatial relations between source and detector by simply redefining the geometry, whereas calibration with radioactive standards requires a separate set of measurements for each source shape and location relative to the detector. Simulation accuracy was evaluated for two large (126% and 110%) and one medium-sized (20%) detectors with radioactive point sources at distances of 10 m, 1.6 m, and 0.50 m and with aqueous solutions in a 0.5-L reentrant beaker and in jars of similar volume but various dimensions. The sensitivity in comparing measured and simulated results was limited by a combined uncertainty of about 3% in the radioactive standards and experimental conditions. Simulation was performed with the MCNP-4 code.

Physical Description

4 p.

Notes

INIS; OSTI as DE97007098

Source

  • ARS `97: American Nuclear Society (ANS) international meeting on advanced reactors safety, Orlando, FL (United States), 1-5 Jun 1997

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE97007098
  • Report No.: ANL/EA/CP--92045
  • Report No.: CONF-970607--30
  • Grant Number: W-31109-ENG-38
  • Office of Scientific & Technical Information Report Number: 508118
  • Archival Resource Key: ark:/67531/metadc691837

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • August 1, 1997

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • May 20, 2016, 1:31 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 12

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Kamboj, Sunita & Kahn, B. Monte Carlo simulation accuracy for calibrating germanium detector photon efficiency, article, August 1, 1997; Illinois. (digital.library.unt.edu/ark:/67531/metadc691837/: accessed September 20, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.