Results of stretched wire field integral measurements on the mini-undulator magnet -- comparison of results obtained from circular and translational motion of the integrating wire
Page:
1 of 12
The following text was automatically extracted from the image on this page using optical character recognition software:
BNL- 65605 Informal Report Results of Stretched Wire Field Integral Measurements on the Mini-Undulator Magnet - Comparison of Results Obtained from Circular and Translational Motion of the Integrating Wire Lorraine Solomon May 1998
DISTRIBUTION OF THIS DOCUMENT IS UNLIMITED
MASTF R
National Synchrotron Light Source Brookhaven National Laboratory, Upton, NY 11973 USA Work performed under the auspices of the U.S. Department of Energy, under contract DE-AC02-98CH10886
Solomon, L.Results of stretched wire field integral measurements on the mini-undulator magnet -- comparison of results obtained from circular and translational motion of the integrating wire,