Tests of the APS X-ray transmitting beam position monitors at ESRF

PDF Version Also Available for Download.

Description

Two different types of synthetic diamond-based X-ray transmitting beam position monitor (XBPM) prototypes have been studied with an undulator white beam at the European Synchrotron Radiation Facility (ESRF) ID-6 beamline. Of particular interest was the possibility of designing an integral window and filter-photon beam position monitor for the Advanced Photon Source (APS) high heat flux insertion device beamlines. The photoelectron-emission type transmitting XBPM prototype uses a 25-mm-diameter, 175-micron-thick CVD-diamond disk with 0.2-micron-thick electrically isolated patterns of aluminum coating on one side of the diamond disk. The photoelectron emission signal was collected from the aluminum-coat surface to provide the beam position ... continued below

Physical Description

3 p.

Creation Information

Shu, D.; Barraza, J.; Kuzay, T.M.; Naylor, G. & Elleaume, P. October 1, 1997.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Authors

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Two different types of synthetic diamond-based X-ray transmitting beam position monitor (XBPM) prototypes have been studied with an undulator white beam at the European Synchrotron Radiation Facility (ESRF) ID-6 beamline. Of particular interest was the possibility of designing an integral window and filter-photon beam position monitor for the Advanced Photon Source (APS) high heat flux insertion device beamlines. The photoelectron-emission type transmitting XBPM prototype uses a 25-mm-diameter, 175-micron-thick CVD-diamond disk with 0.2-micron-thick electrically isolated patterns of aluminum coating on one side of the diamond disk. The photoelectron emission signal was collected from the aluminum-coat surface to provide the beam position information. A novel photoconductive-type transmitting XBPM prototype uses the same CVD-diamond disk, but patterns of aluminum coating were applied on both sides of the diamond disk. A DC bias voltage was used to generate the current signal, which is based on photoconductive properties of the CVD-diamond. Test results are presented in the paper.

Physical Description

3 p.

Notes

INIS; OSTI as DE97053848

Source

  • 17. IEEE particle accelerator conference, Vancouver (Canada), 12-16 May 1997

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE97053848
  • Report No.: ANL/XFD/CP--93879
  • Report No.: CONF-970503--
  • Grant Number: W-31109-ENG-38
  • DOI: 10.2172/555513 | External Link
  • Office of Scientific & Technical Information Report Number: 555513
  • Archival Resource Key: ark:/67531/metadc691237

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 1, 1997

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • Dec. 15, 2015, 11:42 a.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 9

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Shu, D.; Barraza, J.; Kuzay, T.M.; Naylor, G. & Elleaume, P. Tests of the APS X-ray transmitting beam position monitors at ESRF, report, October 1, 1997; Illinois. (digital.library.unt.edu/ark:/67531/metadc691237/: accessed June 25, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.