Thermal analysis of simulated Pantex pit storage Page: 1 of 19
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
UCRL-ID-125467
This is an informal report intended primarily fo
distribution. The opinions and conclusions stated a
or may not be those of the Laboratory.
Work performed under the auspices of the U.S.
Lawrence Livermore National Laboratory under CThermal Analysis of
Simulated Pantex Pit Storage
S. M. Aceves
B. T. Kornblum
October 1996
r internal or limited external
re those of the author and may
Department of Energy by thecontract W-7405-Eng-48.
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Aceves, S.M., Kornblum, B.T. Thermal analysis of simulated Pantex pit storage, report, October 1, 1996; California. (https://digital.library.unt.edu/ark:/67531/metadc690738/m1/1/: accessed April 24, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.