The measurement of liquid levels is the primary method of early leak detection in some underground waste storage tanks at Hanford, as well as for the detection of intrusion of liquids into the tanks. The gauges used for many years for this purpose are no longer available and are rapidly failing. After extensive evaluation and testing, the ENRAF Series 854 level gauge was selected as the primary instrument for monitoring waste surface levels. The material for the wire from which the displacer of the gauge is suspended was selected to be type 316 stainless steel based upon its excellent corrosion ... continued below

Physical Description

5 p.

Creation Information

Anantatmula, R.P. November 16, 1994.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The measurement of liquid levels is the primary method of early leak detection in some underground waste storage tanks at Hanford, as well as for the detection of intrusion of liquids into the tanks. The gauges used for many years for this purpose are no longer available and are rapidly failing. After extensive evaluation and testing, the ENRAF Series 854 level gauge was selected as the primary instrument for monitoring waste surface levels. The material for the wire from which the displacer of the gauge is suspended was selected to be type 316 stainless steel based upon its excellent corrosion resistance in Hanford tank wastes. After approximately 10 weeks of service, the displacer attached to the gauge installed in tank 241-S-106 separated from the wire. It was determined that the wire failure was due to chloride ion stress corrosion cracking of the 316 wire. Radiation induced breakdown of the polyvinyl chloride (PVC) riser liners is suspected to be the source of the chloride ions. The task team proposed short-term and long-term actions. The short-term actions included evaluating the source of the chloride ions, while continuing to monitor liquid levels. One of the long-term actions is the selection of a wire material that is compatible with the PVC liner and the tank waste environment. This document describes the test plan for the selection of one material, from the list of candidate materials, that is the most suitable material for use in the combined environment of the PVC liner and the tank waste. The candidate materials to be tested are Hastelloy C-22, Pt-10% Rh, Pt-20% Rh, and Pt-20% Ir.

Physical Description

5 p.

Notes

INIS; OSTI as DE95010082

Source

  • Other Information: PBD: 16 Nov 1994

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95010082
  • Report No.: WHC-SD-WM-TP--283
  • Grant Number: AC06-87RL10930
  • DOI: 10.2172/52740 | External Link
  • Office of Scientific & Technical Information Report Number: 52740
  • Archival Resource Key: ark:/67531/metadc689781

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 16, 1994

Added to The UNT Digital Library

  • Aug. 14, 2015, 8:43 a.m.

Description Last Updated

  • Feb. 8, 2016, 9:48 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Anantatmula, R.P. Test plan for the selection of the ENRAF gauge wire material, report, November 16, 1994; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc689781/: accessed August 17, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.