vsC-sD-im-ATRt-172
Rev. 0
Pege 15
is at ambient operating temperature between 20 C and 25 C.
4.2 LabVieM VIRTUAL INSTRUM1 ENT DATA BYSTEM
NOTE: EQUIPMENT AND INSTRUMENT DESIGNATOR DEFINITION:
EXAMPLE : FIT - 5- - -
B C D S
A. EQUIPMENT/INSTRUMENT IDENTIFIER PER H-14-020000
B. ONE OR TWO DIGIT TANK FARM LOCATION NUMBER
(1=AN, 31=SY)
C. TWO DIGIT SEQUENTIAL, LOOP OR DEVICE IDENTIFIER
D. ALPHA CHARACTER TANK IDENTIFIER
4.2.1 Teat Preparation
BTEP 1:
Verify that the GCSiHOST computer analog I/O card is
connected to the AMUX card in the Analog drawer.
6TEP 2:
,i Verify that the GCSIHOST computer serial card is connected
to the 5B digital card in the Discrete drawer.
STEP 3:
Verify that all process instruments, which will be processed
by LabView GCSVI.VI, are powered up per the Test Director's
instruction.
BTEP 4:
Place the gas delivery system into normal operating
conditions under System Engineer's direction with the
following parameter settings.
MAIN SAMPLE FLOW: 0.5 CFM / 2.5-3.0" H20
[] GC1 SAMPLE FLOW: 5-10 CC/M
GC2 SAMPLE FLOW: 5-15 CC/M
BTEP 5s
On the GCS1HOST computer, close all active windows under
Program Manager.
STEP 6:
Start LabView program by selecting "GCSVI" icon from GCSAPPS
group.
STEP 7:
Verify that the GCSVI.VI front panel is displayed on the
GC5IHOST computer.
BTEP 8:
Click on the LabView continuous run button to run GCSVI.VI
application.
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Vo, C.V. Gas characterization system software acceptance test report, report, March 28, 1996; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc687547/m1/19/: accessed April 24, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.