Array display tool ADT reference manual. Version 1.2

PDF Version Also Available for Download.

Description

Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position ... continued below

Physical Description

19 p.

Creation Information

Evans, K. Jr. December 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Array Display Tool (ADT) is a Motif program to display arrays of process variables from the Advanced Photon Source control system. A typical use is to display the horizontal and vertical monitor readings. A picture of the ADT interface is here. The screen layout, apart from the menu bar, consists of two types of graphic areas in which the values for the arrays of process variables are shown: Display areas, which display one or more arrays as a function of index, and a zoom area. In the zoom area specified arrays only are displayed as a function of lattice position along with symbols for the major elements of the lattice. There can be several display areas, but at most one zoom area. When the screen is resized these areas change size proportionally. There are a number of options in the View Menu to change the way the values are displayed. It is also possible via the Options Menu to: (1) Store the current values internally. (2) Store the values from a snapshot file internally. (3) Display one of the stored sets of values along with the current values. (4) Display the difference of the current values with one of the stored sets of values. (5) Write the current values to a snapshot file. There are several (currently 5) slots in which you can store values internally. In addition you can display the values with specified reference values subtracted.

Physical Description

19 p.

Notes

INIS; OSTI as DE97002351

Source

  • Other Information: PBD: Dec 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE97002351
  • Report No.: ANL/ASD/RP--88282-VERSION1.2
  • Grant Number: W-31109-ENG-38
  • DOI: 10.2172/451195 | External Link
  • Office of Scientific & Technical Information Report Number: 451195
  • Archival Resource Key: ark:/67531/metadc686908

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 1, 1995

Added to The UNT Digital Library

  • July 25, 2015, 2:21 a.m.

Description Last Updated

  • Dec. 14, 2015, 6:48 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Evans, K. Jr. Array display tool ADT reference manual. Version 1.2, report, December 1, 1995; Illinois. (digital.library.unt.edu/ark:/67531/metadc686908/: accessed December 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.