Report of tests carried out on Viton O-ring seals to assess suitability for operation over the temperature range {minus}40 C to +220 C when used in Package Design 2863B

PDF Version Also Available for Download.

Description

To satisfy the requirements of US Regulatory bodies the O-ring seals in the containment vessels of Package Design 2863B have to be shown to operate satisfactorily (i.e. remain leaktight) at the extremes of temperature that they are expected to experience during both normal and hypothetical accident conditions of transport. For Package Design 2863B this effectively means that the seals must remain leaktight over the temperature range {minus}40 C to + 220 C, but to ensure that an adequate safety margin exists the seals should preferably remain leaktight over the range {minus}50 C to +250 C. This test report describes the … continued below

Physical Description

34 p.

Creation Information

Creator: Unknown. December 31, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 236 times, with 7 in the last month. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

To satisfy the requirements of US Regulatory bodies the O-ring seals in the containment vessels of Package Design 2863B have to be shown to operate satisfactorily (i.e. remain leaktight) at the extremes of temperature that they are expected to experience during both normal and hypothetical accident conditions of transport. For Package Design 2863B this effectively means that the seals must remain leaktight over the temperature range {minus}40 C to + 220 C, but to ensure that an adequate safety margin exists the seals should preferably remain leaktight over the range {minus}50 C to +250 C. This test report describes the procedures and results of tests carried out on Viton seals over the temperature range {minus}50 C to +250 C. The variability of the results at low temperature, by both pressure drop and helium leakage testing, would indicate that the particular formulation of Viton tested cannot be used to provide a reliable leaktight seal at {minus}40 C. Although the results of the pressure drop tests at high temperature were satisfactory, insufficient testing has been carried out using helium leakage testing to draw a firm conclusion about the high temperature performance of the material tested.

Physical Description

34 p.

Notes

INIS; OSTI as DE97002942

Source

  • Other Information: PBD: [1996]

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • December 31, 1996

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • July 28, 2016, 7:24 p.m.

Usage Statistics

When was this report last used?

Yesterday: 1
Past 30 days: 7
Total Uses: 236

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Report of tests carried out on Viton O-ring seals to assess suitability for operation over the temperature range {minus}40 C to +220 C when used in Package Design 2863B, report, December 31, 1996; New Mexico. (https://digital.library.unt.edu/ark:/67531/metadc685118/: accessed April 25, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.