The 1.7-GeV 100-mA CW proton linac is now under design for the Accelerator Production of Tritium (APT) Project. The high current leads to stringent restrictions on allowable beam losses (<1 nA/m), that requires analyzing carefully all possible loss sources. While wake-field effects are usually considered negligible in proton linacs, the author studies these effects for the APT to exclude potential problems at such a high current. Loss factors and resonance frequency spectra of various discontinuities of the vacuum chamber are investigated, both analytically and using 2-D and 3-D simulation codes with a single bunch as well as with many bunches. ... continued below

Physical Description

4 p.

Creation Information

Kurennoy, S.S. December 31, 1998.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

The 1.7-GeV 100-mA CW proton linac is now under design for the Accelerator Production of Tritium (APT) Project. The high current leads to stringent restrictions on allowable beam losses (<1 nA/m), that requires analyzing carefully all possible loss sources. While wake-field effects are usually considered negligible in proton linacs, the author studies these effects for the APT to exclude potential problems at such a high current. Loss factors and resonance frequency spectra of various discontinuities of the vacuum chamber are investigated, both analytically and using 2-D and 3-D simulation codes with a single bunch as well as with many bunches. Here he concentrates on two features specific to the APT linac: loss factors for the design {beta} < 1 and CW beam structure.

Physical Description

4 p.

Notes

INIS; OSTI as DE99002762

Source

  • 19. international linac conference, Chicago, IL (United States), 23-28 Aug 1998

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE99002762
  • Report No.: LA-UR--98-3631
  • Report No.: CONF-980827--
  • Grant Number: W-7405-ENG-36
  • Office of Scientific & Technical Information Report Number: 350983
  • Archival Resource Key: ark:/67531/metadc683940

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • December 31, 1998

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • May 5, 2016, 7:39 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Kurennoy, S.S. Wake field effects in APT linac, article, December 31, 1998; New Mexico. (digital.library.unt.edu/ark:/67531/metadc683940/: accessed September 24, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.