Post-decontamination and dismantlement (D&D) characterization report for CFA-669 site

PDF Version Also Available for Download.

Description

This report presents results of post-decontamination and dismantling (D&D) characterization surveys performed by EG&G Idaho, Inc. (EG&G Idaho), at Central Facilities Area (CFA)-669, which was the Hot Laundry Facility. The site was characterized to determine and document the radiological and chemical conditions of the site following D&D and to determine if the site satisfies the release criteria. Constructed in 1950, CFA-669 served as the ``hot`` and ``cold`` laundry for Idaho National Engineering Laboratory site contractors until the boiler exploded in 1981. The building was shut down at that time. Before D&D activities began in 1992, the facility was characterized and ... continued below

Physical Description

18 p.

Creation Information

Smith, D.L. January 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 12 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

  • Smith, D.L. Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report presents results of post-decontamination and dismantling (D&D) characterization surveys performed by EG&G Idaho, Inc. (EG&G Idaho), at Central Facilities Area (CFA)-669, which was the Hot Laundry Facility. The site was characterized to determine and document the radiological and chemical conditions of the site following D&D and to determine if the site satisfies the release criteria. Constructed in 1950, CFA-669 served as the ``hot`` and ``cold`` laundry for Idaho National Engineering Laboratory site contractors until the boiler exploded in 1981. The building was shut down at that time. Before D&D activities began in 1992, the facility was characterized and the results documented. D&D activities were completed in July 1994. The post-D&D radiological characterization consisted of radiation measurements and analyses of soil samples to identify man-made radionuclides and determine the specific activity of each sample. The chemical characterization consisted of toxicity characterization leaching procedure (TCLP) analysis for metals and for volatile and semivolatile organic contamination.

Physical Description

18 p.

Notes

INIS; OSTI as DE95008670

Source

  • Other Information: PBD: Jan 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95008670
  • Report No.: INEL--94/0138
  • Grant Number: AC07-94ID13223
  • DOI: 10.2172/34454 | External Link
  • Office of Scientific & Technical Information Report Number: 34454
  • Archival Resource Key: ark:/67531/metadc683877

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 1, 1995

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • Feb. 20, 2017, 4:07 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 3
Total Uses: 12

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Smith, D.L. Post-decontamination and dismantlement (D&D) characterization report for CFA-669 site, report, January 1, 1995; Idaho Falls, Idaho. (digital.library.unt.edu/ark:/67531/metadc683877/: accessed September 24, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.