Investigation of the silicon loss in APS MoSi{sub 2} under the range of typical spray conditions

PDF Version Also Available for Download.

Description

MoSi{sub 2} provides good high temperature oxidation and corrosion resistance. However, the lower silicides such as Mo{sub 5}Si{sub 3} do not provide such resistance. In this study, air plasma sprayed (APS) MoSi{sub 2} particle temperatures and velocities were measured under various torch conditions chosen to span the majority of typically utilized spray parameters. Empirical models of particle temperature and velocity were computed from the data. Three spray conditions were chosen to produce high, medium and low particle temperature and velocities. Coatings produced under these spray conditions were characterized by profile tracing, quantitative x-ray diffraction, and SEM analysis. The Mo{sub 5}Si{sub ... continued below

Physical Description

14 p.

Creation Information

Hollis, K.J.; Castro, R.G.; Bartlett, A. & Neiser, R. September 1, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Authors

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

MoSi{sub 2} provides good high temperature oxidation and corrosion resistance. However, the lower silicides such as Mo{sub 5}Si{sub 3} do not provide such resistance. In this study, air plasma sprayed (APS) MoSi{sub 2} particle temperatures and velocities were measured under various torch conditions chosen to span the majority of typically utilized spray parameters. Empirical models of particle temperature and velocity were computed from the data. Three spray conditions were chosen to produce high, medium and low particle temperature and velocities. Coatings produced under these spray conditions were characterized by profile tracing, quantitative x-ray diffraction, and SEM analysis. The Mo{sub 5}Si{sub 3} level in the coatings ranged from 5% to 8% while the Mo{sub 5}Si{sub 3} level in the starting powder was 0.6%. Particle size, particle trajectory, and torch parameters were found to be important factors in the Si loss process when APS depositing MoSi{sub 2}.

Physical Description

14 p.

Notes

INIS; OSTI as DE96011613

Source

  • 9. national thermal spray conference and exposition, Cincinnati, OH (United States), 7-11 Oct 1996

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE96011613
  • Report No.: LA-UR--96-1805
  • Report No.: CONF-961009--4
  • Grant Number: W-7405-ENG-36
  • DOI: 10.2172/373893 | External Link
  • Office of Scientific & Technical Information Report Number: 373893
  • Archival Resource Key: ark:/67531/metadc682978

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 1, 1996

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • March 2, 2016, 1:16 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Hollis, K.J.; Castro, R.G.; Bartlett, A. & Neiser, R. Investigation of the silicon loss in APS MoSi{sub 2} under the range of typical spray conditions, report, September 1, 1996; New Mexico. (digital.library.unt.edu/ark:/67531/metadc682978/: accessed September 26, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.