Expected performance of the CDF plug upgrade calorimeter at TeV33

PDF Version Also Available for Download.

Description

We have evaluated the performance of the CDF plug tile/fiber calorimeter under the radiation environment at a luminosity of 1 x 10{sup 33}cm{sup -2}s{sup -1} at TeV33. The issues covered are the radiation damage, the anode current of photomultipliers, and the energy miss-measurement due to the minimum bias event pile-ups. The plug calorimeter is expected to perform as precision calorimetry in the pseudorapidity range up to {approximately}2.3.

Physical Description

7 p.

Creation Information

Hara, K.; Kim, S. & Takikawa, K. November 1, 1996.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Authors

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

We have evaluated the performance of the CDF plug tile/fiber calorimeter under the radiation environment at a luminosity of 1 x 10{sup 33}cm{sup -2}s{sup -1} at TeV33. The issues covered are the radiation damage, the anode current of photomultipliers, and the energy miss-measurement due to the minimum bias event pile-ups. The plug calorimeter is expected to perform as precision calorimetry in the pseudorapidity range up to {approximately}2.3.

Physical Description

7 p.

Notes

INIS; OSTI as DE97050492

Source

  • 1996 DPF/DPB workshop on new directions for high energy physics, Snowmass, CO (United States), 25 Jun - 12 Jul 1996

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE97050492
  • Report No.: FNAL/C--96/386-E
  • Report No.: CONF-9606243--37
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 437785
  • Archival Resource Key: ark:/67531/metadc679317

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • November 1, 1996

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • Nov. 10, 2016, 4:04 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Hara, K.; Kim, S. & Takikawa, K. Expected performance of the CDF plug upgrade calorimeter at TeV33, article, November 1, 1996; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc679317/: accessed September 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.