Test report for measurement of performance vs temperature of Whittaker Electrochemical Cell

PDF Version Also Available for Download.

Description

This document is the test report that summarizes the results of the tests on the Whittaker cells between the temperatures of -20{degrees}F and +120{degrees}F. These sensors are used on the Rotary Mode Core Sampling (RMCS) flammable gas interlock (FGI), to detect and quantify hydrogen gas. The test consisted of operating five Whittaker electrochemical cells in an environmental chamber that was varied in temperature from -20{degrees}F to +120{degrees}F. As the rate rise of the voltage from the cells changed, after exposure to a gas concentration of 1% hydrogen at the different temperatures, the voltage was recorded on a computer controlled data ... continued below

Physical Description

348 p.

Creation Information

Vargo, G.F., Fluor Daniel Hanford February 13, 1997.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Fluor Daniel Hanford, Inc.
    Publisher Info: Fluor Daniel Hanford, Inc., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This document is the test report that summarizes the results of the tests on the Whittaker cells between the temperatures of -20{degrees}F and +120{degrees}F. These sensors are used on the Rotary Mode Core Sampling (RMCS) flammable gas interlock (FGI), to detect and quantify hydrogen gas. The test consisted of operating five Whittaker electrochemical cells in an environmental chamber that was varied in temperature from -20{degrees}F to +120{degrees}F. As the rate rise of the voltage from the cells changed, after exposure to a gas concentration of 1% hydrogen at the different temperatures, the voltage was recorded on a computer controlled data acquisition system. Analysis of the data was made to determine if the cells maximum output voltages and rise times were effected by temperature.

Physical Description

348 p.

Notes

OSTI as DE98059592

Source

  • Other Information: PBD: 13 Feb 1997

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98059592
  • Report No.: HNF-SD-WM-TRP--274
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/330707 | External Link
  • Office of Scientific & Technical Information Report Number: 330707
  • Archival Resource Key: ark:/67531/metadc674868

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 13, 1997

Added to The UNT Digital Library

  • July 25, 2015, 2:20 a.m.

Description Last Updated

  • June 14, 2016, 12:36 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Vargo, G.F., Fluor Daniel Hanford. Test report for measurement of performance vs temperature of Whittaker Electrochemical Cell, report, February 13, 1997; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc674868/: accessed October 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.