TABLE 7. SUMMARY OF HEAT EXCHANGE TEST RESULTS FOR RUNS 1-10.
(Continued)TEST #
8
DB/WB 240/180
VENTS: CLOSED
BAFFLES 6CELL
CELL
CELL1
2
J3AVERAGE
TEMP F.
145.1
153.7
149.4NET CONDENSATE
(GRAMS)
0
0
112NET BTUs
0.0
0.0
239.4TEST # 9 AVERAGE NET CONDENSATE NET BTUs
TEMP F. (GRAMS)
DB/WB 240/180 CELL 1 102 102 218.0
VENTS: CLOSED CELL 2 149.4 121 258.6
BAFFLES 7 CELL 3 147.6 130 277.8
TEST # 10 AVERAGE NET CONDENSATE NET BTUs
TEMP F. (GRAMS)
DB/WB 190/190 CELL 1 138.4 2762 5903.2
VENTS: CLOSED CELL 2 150.2 3839 8205.1
BAFFLES 5 CELL 3 148.5 3577 7645.156
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Taylor, F. Develop apparatus and process for second-stage drying. Final technical report, September 26, 1994--September 27, 1996, report, January 3, 1997; Granite Falls, Minnesota. (https://digital.library.unt.edu/ark:/67531/metadc674783/m1/59/: accessed April 19, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.