The scaled facility design was based on the three level scaling method; the first level is based on the well established approach obtained from the integral response function, namely integral scaling. This level insures that the stead-state as well as dynamic characteristics of the loops are scaled properly. The second level scaling is for the boundary flow of mass and energy between components; this insures that the flow and inventory are scaled correctly. The third level is focused on key local phenomena and constitutive relations. The facility has 1/4 height and 1/100 area ratio scaling; this corresponds to the volume ... continued below

Physical Description

275 p.

Creation Information

Ishii, M.; Ravankar, S.T. & Dowlati, R. April 1, 1996.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 16 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Authors

Sponsor

Publishers

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The scaled facility design was based on the three level scaling method; the first level is based on the well established approach obtained from the integral response function, namely integral scaling. This level insures that the stead-state as well as dynamic characteristics of the loops are scaled properly. The second level scaling is for the boundary flow of mass and energy between components; this insures that the flow and inventory are scaled correctly. The third level is focused on key local phenomena and constitutive relations. The facility has 1/4 height and 1/100 area ratio scaling; this corresponds to the volume scale of 1/400. Power scaling is 1/200 based on the integral scaling. The time will run twice faster in the model as predicted by the present scaling method. PUMA is scaled for full pressure and is intended to operate at and below 150 psia following scram. The facility models all the major components of SBWR (Simplified Boiling Water Reactor), safety and non-safety systems of importance to the transients. The model component designs and detailed instrumentations are presented in this report.

Physical Description

275 p.

Notes

INIS; OSTI as TI96009343

Source

  • Other Information: PBD: Apr 1996

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: TI96009343
  • Report No.: NUREG/CR--6309
  • Report No.: PU-NE--94/1
  • DOI: 10.2172/220555 | External Link
  • Office of Scientific & Technical Information Report Number: 220555
  • Archival Resource Key: ark:/67531/metadc669876

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • April 1, 1996

Added to The UNT Digital Library

  • June 29, 2015, 9:42 p.m.

Description Last Updated

  • April 22, 2016, 6:45 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 2
Total Uses: 16

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Ishii, M.; Ravankar, S.T. & Dowlati, R. Scientific design of Purdue University Multi-Dimensional Integral Test Assembly (PUMA) for GE SBWR, report, April 1, 1996; Washington D.C.. (digital.library.unt.edu/ark:/67531/metadc669876/: accessed October 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.