Testing fluidized bed incinerators for energy-efficient operation for the Southtowns Sewage Treatment Agency. Final report Page: 4 of 146
This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided to UNT Digital Library by the UNT Libraries Government Documents Department.
Extracted Text
The following text was automatically extracted from the image on this page using optical character recognition software:
TESTING FLUIDIZED BED INCINERATORS FOR
ENERGY-EFFICIENT OPERATION
for the
SOUTHTOWNS SEWAGE TREATMENT AGENCY
Final Report
Prepared for
THE NEW YORK STATE
ENERGY RESEARCH AND DEVELOPMENT AUTHORITY
Lawrence J. Pakenas, P.E.
Senior Project Manager
Prepared by
ERIE COUNTY DEPARTMENT OF ENVIRONMENT AND PLANNING
95 Franklin Street
Buffalo, New York 14202
Gerald L. Devlin, P.E.
Assistant Deputy Commissioner
and
URS CONSULTANTS, INC.
282 Delaware Avenue
Buffalo, New York 14202James Lanzo, P.E.
Project Manager
1613-ERER-MW-91lAr
NYSERDA
Report 96-2;pa UT 0 r
January 1996
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Testing fluidized bed incinerators for energy-efficient operation for the Southtowns Sewage Treatment Agency. Final report, report, January 1, 1996; United States. (https://digital.library.unt.edu/ark:/67531/metadc669063/m1/4/: accessed April 18, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.