Electrical conductivity measurements of aqueous boric acid at 25--350{degree}C at saturation vapor pressure. Final report

PDF Version Also Available for Download.

Description

Electrical conductance measurements of aqueous boric acid solutions (15-110 g/kg-H{sub 2}O {equivalent_to} 0.251--1.815 mol/kg-H{sub 2}O) were measured over the temperature range 25 to 75 C at saturation vapor pressures in glass cells with parallel platinum electrodes. Sixteen series of measurements were made involving three samples of boric acid from different sources. Conductance measurements were also made at 15.5 and 30.5 g/kg-H{sub 2}O over the temperature range 100 to 350 C at 50 C intervals with a metallic cell fitted with concentric platinum electrodes. The specific conductances of H{sub 3}BO{sub 3} (aq)were calculated after correction for the conductance of the solvent ... continued below

Physical Description

17 p.

Creation Information

Ho, P.C. & Palmer, D.A. September 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 204 times , with 14 in the last month . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Electrical conductance measurements of aqueous boric acid solutions (15-110 g/kg-H{sub 2}O {equivalent_to} 0.251--1.815 mol/kg-H{sub 2}O) were measured over the temperature range 25 to 75 C at saturation vapor pressures in glass cells with parallel platinum electrodes. Sixteen series of measurements were made involving three samples of boric acid from different sources. Conductance measurements were also made at 15.5 and 30.5 g/kg-H{sub 2}O over the temperature range 100 to 350 C at 50 C intervals with a metallic cell fitted with concentric platinum electrodes. The specific conductances of H{sub 3}BO{sub 3} (aq)were calculated after correction for the conductance of the solvent (water) and are tabulated in this report. At the specific conditions requested in the project description, namely a concentration of 110 g/kg-H{sub 2}O and 65 C, the specific conductance of boric acid is 293.2 {+-} 1.8 microSiemens/cm based on duplicate measurements of four independent solutions. The results from these tests will be utilized by the Tokamak Physics Experimental Project (TPX).

Physical Description

17 p.

Notes

INIS; OSTI as DE96008762

Source

  • Other Information: PBD: Sep 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE96008762
  • Report No.: ORNL/TM--13185
  • Grant Number: AC05-84OR21400
  • DOI: 10.2172/212521 | External Link
  • Office of Scientific & Technical Information Report Number: 212521
  • Archival Resource Key: ark:/67531/metadc668634

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 1, 1995

Added to The UNT Digital Library

  • June 29, 2015, 9:42 p.m.

Description Last Updated

  • Jan. 19, 2016, 1:03 p.m.

Usage Statistics

When was this report last used?

Yesterday: 1
Past 30 days: 14
Total Uses: 204

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Ho, P.C. & Palmer, D.A. Electrical conductivity measurements of aqueous boric acid at 25--350{degree}C at saturation vapor pressure. Final report, report, September 1, 1995; Tennessee. (digital.library.unt.edu/ark:/67531/metadc668634/: accessed September 23, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.