The waveform analysis for Zarem type high voltage pulse generator

PDF Version Also Available for Download.

Description

The project of the cluster klystron requires a 30 to 40 kV pulse generator to drive the mod-anode. A 30--40 kV pulse generator using Zarem type was developed. A pulse distortion showing a deficiency on the rear top was frequently encountered. This note describes the detail of the pulse forming principle. The encountered distortion was analyzed. Simulations demonstrate the same result. The feature of the spark gap was also addressed. A solution of this problem is given.

Physical Description

13 p.

Creation Information

Zhao, Y. October 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

  • Zhao, Y. Brookhaven National Lab., Upton, NY (United States). Physics Dept.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The project of the cluster klystron requires a 30 to 40 kV pulse generator to drive the mod-anode. A 30--40 kV pulse generator using Zarem type was developed. A pulse distortion showing a deficiency on the rear top was frequently encountered. This note describes the detail of the pulse forming principle. The encountered distortion was analyzed. Simulations demonstrate the same result. The feature of the spark gap was also addressed. A solution of this problem is given.

Physical Description

13 p.

Notes

INIS; OSTI as DE96003730

Source

  • Other Information: PBD: Oct 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE96003730
  • Report No.: BNL--62418
  • Grant Number: AC02-76CH00016
  • DOI: 10.2172/188614 | External Link
  • Office of Scientific & Technical Information Report Number: 188614
  • Archival Resource Key: ark:/67531/metadc664793

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 1, 1995

Added to The UNT Digital Library

  • June 29, 2015, 9:42 p.m.

Description Last Updated

  • Nov. 30, 2015, 1:12 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Zhao, Y. The waveform analysis for Zarem type high voltage pulse generator, report, October 1, 1995; Upton, New York. (digital.library.unt.edu/ark:/67531/metadc664793/: accessed September 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.