CSER 97-001 Criticality safety limits for PFP 26-inch vacuum lineremoval

PDF Version Also Available for Download.

Description

As part of the plutonium stabilization operations in the 234-5Z Building, several runs of 26-inch (26 inches of Hg) process vacuum header, along with associated smaller piping is to be cut into sections and disposed of. This criticality safety evaluation report (CSER) requested by Nirider (1996) addresses the removal of several hundred feet of abandoned 3 and 4 inch nominal diameter vacuum header and associated smaller diameter piping runs located in the duct level of the 234-5Z Building in rooms 262, 263, and 264 as shown in the two attached drawings.

Physical Description

22 p.

Creation Information

Himes, D. A. February 14, 1997.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 17 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Fluor Daniel Hanford, Inc.
    Publisher Info: Fluor Daniel Hanford, Inc., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

As part of the plutonium stabilization operations in the 234-5Z Building, several runs of 26-inch (26 inches of Hg) process vacuum header, along with associated smaller piping is to be cut into sections and disposed of. This criticality safety evaluation report (CSER) requested by Nirider (1996) addresses the removal of several hundred feet of abandoned 3 and 4 inch nominal diameter vacuum header and associated smaller diameter piping runs located in the duct level of the 234-5Z Building in rooms 262, 263, and 264 as shown in the two attached drawings.

Physical Description

22 p.

Notes

OSTI as DE98059614

Subjects

Keywords

STI Subject Categories

Source

  • Other Information: PBD: 14 Feb 1997

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE98059614
  • Report No.: HNF-SD-SQA-CSA--526
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/289370 | External Link
  • Office of Scientific & Technical Information Report Number: 289370
  • Archival Resource Key: ark:/67531/metadc664214

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • February 14, 1997

Added to The UNT Digital Library

  • June 29, 2015, 9:42 p.m.

Description Last Updated

  • June 14, 2016, 6:48 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 17

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Himes, D. A. CSER 97-001 Criticality safety limits for PFP 26-inch vacuum lineremoval, report, February 14, 1997; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc664214/: accessed September 19, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.