An electrical-type meter has been developed for measuring mass rates of flow of gasoline or other nonconducting fluids. Its temperature dependence is small over a large range and it has no known vibrational or viscosity errors. The maximum temperature rise is less than 5 C. The rates of flow, measurable within 1% with the present instrument, are approximately 100 to 1,000 or more pounds of gasoline per hour when a potentiometer is used, or 100 to 300 pounds per hour when a deflection-type meter is used.

Creation Information

Tozier, Robert E. September 1939.

Context

This report is part of the collection entitled: National Advisory Committee for Aeronautics Collection and one other and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 50 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Originator

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Titles

Description

An electrical-type meter has been developed for measuring mass rates of flow of gasoline or other nonconducting fluids. Its temperature dependence is small over a large range and it has no known vibrational or viscosity errors. The maximum temperature rise is less than 5 C. The rates of flow, measurable within 1% with the present instrument, are approximately 100 to 1,000 or more pounds of gasoline per hour when a potentiometer is used, or 100 to 300 pounds per hour when a deflection-type meter is used.

Subjects

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • URL: http://hdl.handle.net/2060/20090015030 External Link
  • Report No.: NACA-SR-127
  • Center for AeroSpace Information Number: 20090015030
  • Archival Resource Key: ark:/67531/metadc65091

Collections

This report is part of the following collections of related materials.

National Advisory Committee for Aeronautics Collection

The National Advisory Committee for Aeronautics (NACA) was a U.S. federal agency founded on March 3, 1915 to undertake, promote, and institutionalize aeronautical research. On October 1, 1958 the agency was dissolved, and its assets and personnel transferred to the newly created National Aeronautics and Space Administration (NASA).

Technical Report Archive and Image Library

This selection of materials from the Technical Report Archive and Image Library (TRAIL) includes hard-to-find reports published by various government agencies. The technical publications contain reports, images, and technical descriptions of research performed for U.S. government agencies. Topics range from mining, desalination, and radiation to broader physics, biology, and chemistry studies. Some reports include maps, foldouts, blueprints, and other oversize materials.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 1939

Added to The UNT Digital Library

  • Nov. 17, 2011, 5:13 p.m.

Description Last Updated

  • Oct. 24, 2017, 9:41 a.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 50

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Tozier, Robert E. An electrical-type indicating fuel flowmeter, report, September 1939; (digital.library.unt.edu/ark:/67531/metadc65091/: accessed November 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.