When the APS storage ring was retuned to provide smaller {beta}{sub y} values in the insertion straight sections, it was necessary to increase the vertical tune by at least two units. Since the design values for the horizontal and vertical tunes are 35.22 and 16.30, respectively, this put the tunes dangerously close to the sextupole 2v{sub y}-v{sub x} coupling resonance. The large injection horizontal oscillations could couple to the vertical plane and exceed the 5-mm vertical apertures that exist in some of the insertion straight sections. To avoid this resonance, the vertical tune was raised beyond the resonance to 19.30. ... continued below

Physical Description

13 p.

Creation Information

Chae, Y.-C. & Crosbie, E.A. September 11, 1999.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

When the APS storage ring was retuned to provide smaller {beta}{sub y} values in the insertion straight sections, it was necessary to increase the vertical tune by at least two units. Since the design values for the horizontal and vertical tunes are 35.22 and 16.30, respectively, this put the tunes dangerously close to the sextupole 2v{sub y}-v{sub x} coupling resonance. The large injection horizontal oscillations could couple to the vertical plane and exceed the 5-mm vertical apertures that exist in some of the insertion straight sections. To avoid this resonance, the vertical tune was raised beyond the resonance to 19.30. The result was a reduction in the ability of the chromaticity sextuples to correct the chromaticity. Recent investigation has shown that the chromaticity correction capability of the sextuples can be greatly increased by a modest increase in the horizontal tune. Increasing the horizontal tune by one unit and reducing the vertical tune by three units produces a lattice with better chromaticity control while maintaining an acceptable dynamic aperture.

Physical Description

13 p.

Notes

INIS; OSTI as DE00012097

Medium: P; Size: 13 pages

Source

  • Other Information: PBD: 11 Sep 1999

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: LS-279
  • Grant Number: W-31109-ENG-38
  • DOI: 10.2172/12097 | External Link
  • Office of Scientific & Technical Information Report Number: 12097
  • Archival Resource Key: ark:/67531/metadc626657

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • September 11, 1999

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 7, 2017, 1:12 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 4

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Chae, Y.-C. & Crosbie, E.A. Retuning the APS storage ring for better chromaticity correction., report, September 11, 1999; Illinois. (digital.library.unt.edu/ark:/67531/metadc626657/: accessed October 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.