P-Area Reactor 1993 annual groundwater monitoring report

PDF Version Also Available for Download.

Description

Groundwater was sampled and analyzed during 1993 from wells monitoring the water table at the following locations in P Area: well P 24A in the eastern section of P Area, the P-Area Acid/Caustic Basin, the P-Area Coal Pile Runoff Containment Basin, the P-Area Disassembly Basin, the P-Area Burning/Rubble Pit, and the P-Area Seepage Basins. During 1993, pH was above its alkaline standard in well P 24A. Specific conductance was above its standard in one well each from the PAC and PCB series. Lead exceeded its 50 {mu}g/L standard in one well of the PDB series during one quarter. Tetrachloroethylene and ... continued below

Physical Description

250 p.

Creation Information

Creator: Unknown. November 1, 1994.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Creator

  • We've been unable to identify the creator(s) of this report.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Groundwater was sampled and analyzed during 1993 from wells monitoring the water table at the following locations in P Area: well P 24A in the eastern section of P Area, the P-Area Acid/Caustic Basin, the P-Area Coal Pile Runoff Containment Basin, the P-Area Disassembly Basin, the P-Area Burning/Rubble Pit, and the P-Area Seepage Basins. During 1993, pH was above its alkaline standard in well P 24A. Specific conductance was above its standard in one well each from the PAC and PCB series. Lead exceeded its 50 {mu}g/L standard in one well of the PDB series during one quarter. Tetrachloroethylene and trichloroethylene were detected above their final primary drinking water standards in one well of the PRP well series. Tritium was consistently above its DWS in the PDB and PSB series. Also during 1993, radium-228 exceeded the DWS for total radium in three wells of the PAC series and one well of the PCB series; total alpha-emitting radium exceeded the same standard in a different PCB well. These results are fairly consistent with those from previous years. Unlike results from past years, however, no halogenated volatiles other than trichloroethylene and tetrachloroethylene exceeded DWS in the PRP well series although gas chromatographic volatile organic analyses were performed throughout the year. Some of the regulated units in P Area appear to need additional monitoring by new wells because there are insufficient downgradient wells, sometimes because the original well network, installed prior to regulation, included sidegradient rather than downgradient wells. No monitoring wells had been installed through 1993 at one of the RCRA/CERCLA units named in the Federal Facilities Agreement, the Bingham Pump Outage Pits.

Physical Description

250 p.

Notes

INIS; OSTI as DE96002904

Source

  • Other Information: PBD: Nov 1994

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE96002904
  • Report No.: WSRC-TR--94-0355
  • Grant Number: AC09-89SR18035
  • DOI: 10.2172/137417 | External Link
  • Office of Scientific & Technical Information Report Number: 137417
  • Archival Resource Key: ark:/67531/metadc625870

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 1, 1994

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • Feb. 9, 2016, 6:02 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

P-Area Reactor 1993 annual groundwater monitoring report, report, November 1, 1994; Aiken, South Carolina. (digital.library.unt.edu/ark:/67531/metadc625870/: accessed August 17, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.