4.i5-2 Trends in Chemical Composition of Extracted Pore
Water Versus Axial Pressure Applied During Compression
for Nonwelded Tuff Samples ......... ....... 157
4.15-3 Pore Water Volume Extracted Versus Initial Moisture
Content for Triaxial Compression of Nonwelded Tuff
Samples Best Fit Lines are Based on Regression Analysis 161
4.15-4 Pore Water Volume Extracted Versus Initial Moisture
Content for Uniaxial Compression........ . . . . . 165
4.15-5 Pore Water Volume Extracted Versus Total Axial Strain
for Uniaxial Compression of Welded Tuff Best Fit Line
is Based on Regression Analysis. . ... .......166
4.15-6 Pore Water Volume Extracted Versus Initial Moisture
Content for All Tests Using Nonwelded Tuff Best Fit
Lines are Based on Regression Analysis . ....... 168
4.16-1 Controlled-Blasting Investigation Room and
Instrumentation Alcove-Plan and Section .. ...... 174
4.17-1 Plan View: Thermal Stress Prototype Test ....... 181
4.17-2 Cross Section: Thermal Stress Prototype Test .....182
4.18-1 IS-2 Overcore Hole in Demonstration Drift (G-Tunnel)
Showing Air-Seal Collar and Dust Suppression Equipment 196
4.18-2 IS-4 Overcore Hole in Laser Drift (G-Tunnel) .... ..196
4.18-3 Drill-String Assembly Used for Horizontal Overcore Holes.
(The Stabilizers Fit Over the BQ Rods and Do Not Rotate,
Eliminating or Greatly Reducing Detrimental Drill-String
Chatter)............ ......... . . . 198
4.18-4 Six-Inch Tricone Bit Fitted with a Pilot "Stinger"
That Makes This Bit Follow the Previously Drilled
EX Pilot Hole ...... . . . . ........... 198
4.18-5 EX Two-Port Plug Bit Used for Both Air- and Water-Drilling
of the Pilot Hole for the Overcore Test ... .... 200
4.18-6 Probex-I (NX) Dilatometer (in Box) Showing Expandable
Membrane (Standing Upright), Aluminum (Thick Wall),
and Steel (Thin Wall) Calibration Cylinders . . . . . . 201vii
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Oliver, R.D. & Kalia, H.N. Status report on ESF-related prototype testing, report, December 1, 1992; New Mexico. (https://digital.library.unt.edu/ark:/67531/metadc624947/m1/4/: accessed March 29, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.