Description

It is the purpose of this report to describe the thinking and work that went into thoroughly understanding, a specific eddy current septum magnet that will be used in the APS and needs ``fixing.`` The goal is to go beyond mere qualitative understanding and carry the analysis far enough to recognize the real problems of this magnet and to develop the tools to solve them. While it would be very tempting to write this report in very general terms, it would be very difficult to achieve complete generality, and one would risk losing the focus on this specific magnet that ... continued below

Physical Description

29 p.

Creation Information

Halbach, K. August 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 42 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

  • Halbach, K. Lawrence Berkeley Lab., CA (United States)

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

It is the purpose of this report to describe the thinking and work that went into thoroughly understanding, a specific eddy current septum magnet that will be used in the APS and needs ``fixing.`` The goal is to go beyond mere qualitative understanding and carry the analysis far enough to recognize the real problems of this magnet and to develop the tools to solve them. While it would be very tempting to write this report in very general terms, it would be very difficult to achieve complete generality, and one would risk losing the focus on this specific magnet that needs to have an improved performance. The discussion contains, however, so many generally useful concepts and procedures that it might further be useful for designers of other eddy current septum magnets both at the APS and elsewhere. Since it is necessary not only to have a deep qualitative understanding of several aspects of this type of magnet, but also to quantitatively assess what has to be done to achieve the desired performance, fairly heavy use of mathematical tools was made. In doing so it became clear that the extensive use of these tools is essential not only for this purpose, but also to get the required good qualitative understanding of the device. For instance, it turns out that in this particular instance, an important part of the underlying physics does not become clear until one seems to run into what one might consider, at first, a mathematical problem, whose resolution is not clear until one has found the solution, which then seems ``obvious.`` Even though iron in the septum has a nonlinear relationship between B and H, assuming a constant permeability is sufficient to obtain the information needed to develop a sufficient understanding of the magnet to make some crucial decisions.

Physical Description

29 p.

Notes

INIS; OSTI as DE95015830

Source

  • Other Information: PBD: [1995]

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95015830
  • Report No.: LS--244
  • Grant Number: W-31-109-ENG-38
  • DOI: 10.2172/105728 | External Link
  • Office of Scientific & Technical Information Report Number: 105728
  • Archival Resource Key: ark:/67531/metadc624631

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • August 1, 1995

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • Dec. 14, 2015, 12:36 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 42

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Halbach, K. Some thoughts on an eddy current septum magnet, report, August 1, 1995; Illinois. (digital.library.unt.edu/ark:/67531/metadc624631/: accessed November 19, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.