Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94

PDF Version Also Available for Download.

Description

This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included ... continued below

Physical Description

28 p.

Creation Information

Clauss, T.W.; Ligotke, M.W. & Pool, K.H. October 1, 1995.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Pacific Northwest Laboratory
    Publisher Info: Pacific Northwest Lab., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-BY-107 (referred to as Tank BY-107). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The organic analytes for TO-14 compounds were extended to include 15 analytes identified by the Toxicological Review Panel for Tank C-103 and reported in Toxicological Evaluation of Analytes from Tank 241-C-103 PAE-10189. While these analytes are only of toxicological concern for Tank C-103, program management included these analytes for future tank analyses as identified in the fiscal year work plan. This plan is attached to a letter dated 9/30/94 and addressed to Mr. T. J. Kelly of WHC. The plan also requires PNL to analyze for the permanent gases as shown in Table 3.5. The sample job was designated S4077, and samples were collected by WHC on October 26, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses), and six SUMMA{trademark} canisters (for organic analyses) were supplied to the WHC sampling staff on October 24. Samples were taken (by WHC) from the tank headspace on October 26 and were returned to PNL from the field on November 8. Inorganic (sorbent trap) samples were delivered to PNL on chain of custody (COC) 008071. The SUMMA{trademark} canisters were delivered on COC 008070. Three SUMMA{trademark} canister samples were stored at the PNL 326/23B laboratory pending further instruction from WHC to send them to the Oregon Graduate Institute (OGI) for analysis.

Physical Description

28 p.

Notes

INIS; OSTI as DE96002222

Source

  • Other Information: PBD: Oct 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE96002222
  • Report No.: PNL--10468
  • Grant Number: AC06-76RL01830
  • DOI: 10.2172/125426 | External Link
  • Office of Scientific & Technical Information Report Number: 125426
  • Archival Resource Key: ark:/67531/metadc624201

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 1, 1995

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 7, 2016, 3:18 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Clauss, T.W.; Ligotke, M.W. & Pool, K.H. Vapor space characterization of waste tank 241-BY-107: Results from samples collected on 10/26/94, report, October 1, 1995; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc624201/: accessed August 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.