SCD1-general-purpose single-crystal diffractometer-reference instrument WBS 1.7.5.

PDF Version Also Available for Download.

Description

SCD1 is intended to satisfy most needs for small-unit-cell single-crystal diffraction. Figure 1 provides a schematic representation of SCD1, and Table 1 gives the parameters for this instrument. This instrument will provide much faster data collection than any existing time-of-flight single-crystal diffractometer. The goal is data collection times of 1 hour for a simple structure and 1 day for a medium-complexity structure.

Physical Description

9 p.

Creation Information

Crawford, R.K. January 20, 1999.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 26 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

SCD1 is intended to satisfy most needs for small-unit-cell single-crystal diffraction. Figure 1 provides a schematic representation of SCD1, and Table 1 gives the parameters for this instrument. This instrument will provide much faster data collection than any existing time-of-flight single-crystal diffractometer. The goal is data collection times of 1 hour for a simple structure and 1 day for a medium-complexity structure.

Physical Description

9 p.

Notes

INIS; OSTI as DE00012077

Medium: P; Size: 9 pages

Source

  • Other Information: PBD: 20 Jan 1999

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: ANL/SNS/98-4
  • Grant Number: W-31109-ENG-38
  • DOI: 10.2172/12077 | External Link
  • Office of Scientific & Technical Information Report Number: 12077
  • Archival Resource Key: ark:/67531/metadc622777

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 20, 1999

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 11, 2017, 9:05 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 26

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Crawford, R.K. SCD1-general-purpose single-crystal diffractometer-reference instrument WBS 1.7.5., report, January 20, 1999; Illinois. (digital.library.unt.edu/ark:/67531/metadc622777/: accessed September 23, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.