The Multi-Canister Overpack (MCO) rupture disk precludes the MCO from pressurization above the design limit during transport from the K Basins to the Cold Vacuum Drying (CVD) Facility and prior to connection of the CVD process piping. Removal of the rupture disk from the MCO design would: (a) result in unacceptable dose consequences in the event a thermal runaway accident occurred; (b) increase residual risk; and (c) remove a degree of specificity from the dose calculations. The potential cost savings of removing the rupture disk from the MCO design is offset by the cost of design modifications, changes to hazard ... continued below

Physical Description

8 pages

Creation Information

SMITH, K.E. November 3, 1998.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. It has been viewed 14 times . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Author

Sponsor

Publisher

  • Hanford Site (Wash.)
    Publisher Info: HNF Hanford Site (United States)
    Place of Publication: United States

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

The Multi-Canister Overpack (MCO) rupture disk precludes the MCO from pressurization above the design limit during transport from the K Basins to the Cold Vacuum Drying (CVD) Facility and prior to connection of the CVD process piping. Removal of the rupture disk from the MCO design would: (a) result in unacceptable dose consequences in the event a thermal runaway accident occurred; (b) increase residual risk; and (c) remove a degree of specificity from the dose calculations. The potential cost savings of removing the rupture disk from the MCO design is offset by the cost of design modifications, changes to hazard analyses and safety analyses, and changes to existing documentation. Retaining the rupture disk mitigates the consequences of MCO overpressurization, and considering the overall economic impacts to the SNF Project, is the most cost effective approach.

Physical Description

8 pages

Notes

INIS; OSTI as DE00011252

Source

  • Other Information: PBD: 3 Nov 1998

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Report No.: HNF--3399--REV0
  • Report No.: EW7040000
  • Grant Number: AC06-96RL13200
  • DOI: 10.2172/11252 | External Link
  • Office of Scientific & Technical Information Report Number: 11252
  • Archival Resource Key: ark:/67531/metadc621551

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • November 3, 1998

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 27, 2016, 4:24 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 14

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

SMITH, K.E. Multi-Canister overpack necessity of the rupture disk, report, November 3, 1998; United States. (digital.library.unt.edu/ark:/67531/metadc621551/: accessed December 12, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.