Lattice function measurement with TBT BPM data

PDF Version Also Available for Download.

Description

At Fermilab Main Ring some of the Beam Position Monitors (BPM) are instrumented with Turn-By-Turn (TBT) capability to record up to 1,024 consecutive turns of BPM data for each given trigger. For example, there are 9 horizontal plane and 8 vertical plane BPM`s in the sector D3 and D4. The BPM data, which records the betatron oscillation, is fitted to obtain beam parameters x, x{prime}, y, y{prime}, and {Delta}p/p, using the calculated beam line transfer matrix. The resulted TBT beam parameters (x, x{prime}) or (y, y{prime}) are fitted to ellipses to obtain the lattice function {beta}, {alpha}, and the emittance ... continued below

Physical Description

26 p.

Creation Information

Yang, M.J. June 1, 1995.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

At Fermilab Main Ring some of the Beam Position Monitors (BPM) are instrumented with Turn-By-Turn (TBT) capability to record up to 1,024 consecutive turns of BPM data for each given trigger. For example, there are 9 horizontal plane and 8 vertical plane BPM`s in the sector D3 and D4. The BPM data, which records the betatron oscillation, is fitted to obtain beam parameters x, x{prime}, y, y{prime}, and {Delta}p/p, using the calculated beam line transfer matrix. The resulted TBT beam parameters (x, x{prime}) or (y, y{prime}) are fitted to ellipses to obtain the lattice function {beta}, {alpha}, and the emittance associated with the betatron oscillation. The tune of the machine can be calculated from the phase space angles of the successive turns, in the normalized phase space. The beam parameters can also be used to extract transfer matrix to be used for local and global coupling analysis. The process of fitting the BPM data produces information that can be used to diagnose problems such as calibration, noise level and polarity. Being available at every turn and at changing beam position the information carries a lot of statistical power. Since most of the BPM`s are located at high beta location only the x and y beam position information is not simultaneously available. The BPM data fitting processing essentially bridged the gap.

Physical Description

26 p.

Notes

INIS; OSTI as DE95016184

Source

  • 16. Institute of Electrical and Electronic Engineers (IEEE) particle accelerator conference, Dallas, TX (United States), 1-5 May 1995

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE95016184
  • Report No.: FNAL--TM-1922
  • Report No.: CONF-950512--311
  • Grant Number: AC02-76CH03000
  • Office of Scientific & Technical Information Report Number: 102200
  • Archival Resource Key: ark:/67531/metadc621511

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • June 1, 1995

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 1, 2016, 6:53 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 8

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Yang, M.J. Lattice function measurement with TBT BPM data, article, June 1, 1995; Batavia, Illinois. (digital.library.unt.edu/ark:/67531/metadc621511/: accessed August 19, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.