We give a description for the production of {sup 13}C foils and the preparation of an approximately 1 mg/cm{sup 2} thick target. A recent experiment to measure the mass of {sup 36}Ca via the {sup 40}Ca({sup 4}He,{sup 8}He){sup 36}Ca reaction at the S800 magnetic spectrometer at MSU, needed a precise determination of the beam energy and calibration of the focal plane of the magnetic spectrometer in order to achieve the most accurate value for the {sup 36}Ca mass. The 1 mg/cm{sup 2} {sup 13}C target was essential for these purposes. Target performance along with some preliminary results will also be ... continued below

Physical Description

10 p.

Creation Information

Greene, J. P. November 18, 1998.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Author

Sponsor

Publisher

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

We give a description for the production of {sup 13}C foils and the preparation of an approximately 1 mg/cm{sup 2} thick target. A recent experiment to measure the mass of {sup 36}Ca via the {sup 40}Ca({sup 4}He,{sup 8}He){sup 36}Ca reaction at the S800 magnetic spectrometer at MSU, needed a precise determination of the beam energy and calibration of the focal plane of the magnetic spectrometer in order to achieve the most accurate value for the {sup 36}Ca mass. The 1 mg/cm{sup 2} {sup 13}C target was essential for these purposes. Target performance along with some preliminary results will also be discussed.

Physical Description

10 p.

Notes

INIS; OSTI as DE00010937

Medium: P; Size: 10 pages

Source

  • 19th World Conference of the International Nuclear Target Development Society, Oak Ridge, TN (US), 10/05/1998--10/09/1998

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Report No.: ANL/PHY/CP-97115
  • Grant Number: W-31109-ENG-38
  • Office of Scientific & Technical Information Report Number: 10937
  • Archival Resource Key: ark:/67531/metadc620069

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • November 18, 1998

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • April 6, 2017, 6:52 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 3

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Greene, J. P. Preparation of a 1 mg/cm{sup 2} {sup 13}C target., article, November 18, 1998; Illinois. (digital.library.unt.edu/ark:/67531/metadc620069/: accessed September 22, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.