Preliminary groundwater analyses were performed for the Hanford Environmental Restoration Disposal Facility (ERDF) to demonstrate compliance With dose limit performance objectives in DOE Order 5820.2A. These analyses were designed to determine peak radionuclide concentrations in a theoretical drinking-water well 100 m downstream from the facility. The resulting peak concentrations can be used to determine inventory limits for the facility.

Physical Description

13 p.

Creation Information

Finfrock, S.H. October 1, 1994.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Westinghouse Hanford Company
    Publisher Info: Westinghouse Hanford Co., Richland, WA (United States)
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Preliminary groundwater analyses were performed for the Hanford Environmental Restoration Disposal Facility (ERDF) to demonstrate compliance With dose limit performance objectives in DOE Order 5820.2A. These analyses were designed to determine peak radionuclide concentrations in a theoretical drinking-water well 100 m downstream from the facility. The resulting peak concentrations can be used to determine inventory limits for the facility.

Physical Description

13 p.

Notes

INIS; OSTI as DE95015741

Source

  • International conference on mathematics and computations, reactor physics, and environmental analyses, Portland, OR (United States), 30 Apr - 4 May 1995

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

  • Other: DE95015741
  • Report No.: WHC-SA--2665
  • Report No.: CONF-950420--31
  • Grant Number: AC06-87RL10930
  • DOI: 10.2172/106658 | External Link
  • Office of Scientific & Technical Information Report Number: 106658
  • Archival Resource Key: ark:/67531/metadc618577

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 1, 1994

Added to The UNT Digital Library

  • June 16, 2015, 7:43 a.m.

Description Last Updated

  • Feb. 8, 2016, 8:53 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 2

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Finfrock, S.H. Modeling groundwater contamination transport for the Hanford Environmental Disposal Facility, report, October 1, 1994; Richland, Washington. (digital.library.unt.edu/ark:/67531/metadc618577/: accessed August 18, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; crediting UNT Libraries Government Documents Department.