This investigation dealt with locating and measuring x-ray absorption of radiographic images. The methods developed provide a fast, accurate, minicomputer control, for analysis of embedded objects. A PDP/8 computer system was interfaced with a Joyce Loebl 3CS Microdensitometer and a Leeds & Northrup Recorder. Proposed algorithms for bone location and data smoothing work on a twelve-bit minicomputer. Designs of a software control program and operational procedure are presented. The filter made wedge and limb scans monotonic from minima to maxima. It was tested for various convoluted intervals. Ability to resmooth the same data in multiple passes was tested. An interval ... continued below

Physical Description

vii, 121 leaves: ill.

Creation Information

Buckner, Richard L. August 1976.

Context

This thesis is part of the collection entitled: UNT Theses and Dissertations and was provided by UNT Libraries to Digital Library, a digital repository hosted by the UNT Libraries. More information about this thesis can be viewed below.

Who

People and organizations associated with either the creation of this thesis or its content.

Chair

Committee Member

Publisher

Rights Holder

For guidance see Citations, Rights, Re-Use.

  • Buckner, Richard L.

Provided By

UNT Libraries

With locations on the Denton campus of the University of North Texas and one in Dallas, UNT Libraries serves the school and the community by providing access to physical and online collections; The Portal to Texas History and UNT Digital Libraries; academic research, and much, much more.

Contact Us

What

Descriptive information to help identify this thesis. Follow the links below to find similar items on the Digital Library.

Degree Information

Description

This investigation dealt with locating and measuring x-ray absorption of radiographic images. The methods developed provide a fast, accurate, minicomputer control, for analysis of embedded objects. A PDP/8 computer system was interfaced with a Joyce Loebl 3CS Microdensitometer and a Leeds & Northrup Recorder. Proposed algorithms for bone location and data smoothing work on a twelve-bit minicomputer. Designs of a software control program and operational procedure are presented. The filter made wedge and limb scans monotonic from minima to maxima. It was tested for various convoluted intervals. Ability to resmooth the same data in multiple passes was tested. An interval size of fifteen works well in one pass.

Physical Description

vii, 121 leaves: ill.

Language

Identifier

Unique identifying numbers for this thesis in the Digital Library or other systems.

Collections

This thesis is part of the following collection of related materials.

UNT Theses and Dissertations

Theses and dissertations represent a wealth of scholarly and artistic content created by masters and doctoral students in the degree-seeking process. Some ETDs in this collection are restricted to use by the UNT community.

What responsibilities do I have when using this thesis?

When

Dates and time periods associated with this thesis.

Creation Date

  • August 1976

Added to The UNT Digital Library

  • May 10, 2015, 6:16 a.m.

Description Last Updated

  • July 11, 2016, 12:05 p.m.

Usage Statistics

When was this thesis last used?

Yesterday: 0
Past 30 days: 2
Total Uses: 9

Interact With This Thesis

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Buckner, Richard L. Computerized Analysis of Radiograph Images of Embedded Objects as Applied to Bone Location and Mineral Content Measurement, thesis, August 1976; Denton, Texas. (digital.library.unt.edu/ark:/67531/metadc503985/: accessed December 16, 2017), University of North Texas Libraries, Digital Library, digital.library.unt.edu; .