Detector Comparison for Simultaneous Determination of Organic Acids and Inorganic Anions

PDF Version Also Available for Download.

Description

The research reported here is a study of detector systems to determine those most suited for simultaneous organic acid, inorganic anion determination. Comparisons are made on the basis of detection limits and sensitivities for conductivity, UV/Vis, photoconductivity, and derivative conductivity detection systems. The investigation was made using a constant chromatographic system with the only variable component being the detector system. Eluant optimization conditions for each detector are reported along with tables reporting detection limits and sensitivities for each detector system. Various chromatograms are also shown to provide a visual comparison between detector results.

Physical Description

v, 45 leaves: ill.

Creation Information

Pannell, Daniel K. (Daniel Kirk) August 1988.

Context

This thesis is part of the collection entitled: UNT Theses and Dissertations and was provided by UNT Libraries to Digital Library, a digital repository hosted by the UNT Libraries. More information about this thesis can be viewed below.

Who

People and organizations associated with either the creation of this thesis or its content.

Chair

Committee Members

Publisher

Rights Holder

For guidance see Citations, Rights, Re-Use.

  • Pannell, Daniel K. (Daniel Kirk)

Provided By

UNT Libraries

With locations on the Denton campus of the University of North Texas and one in Dallas, UNT Libraries serves the school and the community by providing access to physical and online collections; The Portal to Texas History and UNT Digital Libraries; academic research, and much, much more.

Contact Us

What

Descriptive information to help identify this thesis. Follow the links below to find similar items on the Digital Library.

Degree Information

Description

The research reported here is a study of detector systems to determine those most suited for simultaneous organic acid, inorganic anion determination. Comparisons are made on the basis of detection limits and sensitivities for conductivity, UV/Vis, photoconductivity, and derivative conductivity detection systems. The investigation was made using a constant chromatographic system with the only variable component being the detector system. Eluant optimization conditions for each detector are reported along with tables reporting detection limits and sensitivities for each detector system. Various chromatograms are also shown to provide a visual comparison between detector results.

Physical Description

v, 45 leaves: ill.

Language

Identifier

Unique identifying numbers for this thesis in the Digital Library or other systems.

Collections

This thesis is part of the following collection of related materials.

UNT Theses and Dissertations

Theses and dissertations represent a wealth of scholarly and artistic content created by masters and doctoral students in the degree-seeking process. Some ETDs in this collection are restricted to use by the UNT community.

What responsibilities do I have when using this thesis?

When

Dates and time periods associated with this thesis.

Creation Date

  • August 1988

Added to The UNT Digital Library

  • March 9, 2015, 8:15 a.m.

Description Last Updated

  • Nov. 27, 2017, 10:51 a.m.

Usage Statistics

When was this thesis last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 7

Interact With This Thesis

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

Citations, Rights, Re-Use

Pannell, Daniel K. (Daniel Kirk). Detector Comparison for Simultaneous Determination of Organic Acids and Inorganic Anions, thesis, August 1988; Denton, Texas. (digital.library.unt.edu/ark:/67531/metadc500456/: accessed April 24, 2018), University of North Texas Libraries, Digital Library, digital.library.unt.edu; .