The operating conditions to which the special Mark VIII quatrefoils will be exposed during the proposed piloting program have been compared with the conditions required to cause burnout, using an established method of calculating these conditions. The results of this comparison permit the following conclusions to be drawn: (1) With normal flow of coolant through the special elements the heat flux to be encountered in the R-8 cycle (1400 MW) will be 70% or that required to cause burnout (30% margin from burnout). (2) With a reduction of coolant flow to 82% of normal through one tube of a special …
continued below
Publisher Info:
Du Pont de Nemours (E.I.) and Co., Wilmington, DE (United States). Explosives Dept.
Place of Publication:
Wilmington, Delaware
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The operating conditions to which the special Mark VIII quatrefoils will be exposed during the proposed piloting program have been compared with the conditions required to cause burnout, using an established method of calculating these conditions. The results of this comparison permit the following conclusions to be drawn: (1) With normal flow of coolant through the special elements the heat flux to be encountered in the R-8 cycle (1400 MW) will be 70% or that required to cause burnout (30% margin from burnout). (2) With a reduction of coolant flow to 82% of normal through one tube of a special element, burnout of that fuel column is possible in the R-8 cycle. (3) In the R-6 cycle (1280 MW), the margin from burnout in the special Mark VIII quatrefoils is 42% with full flow and 20% with the above reduced coolant flow. A similar comparison of operating conditions predicted for the L-3 cycle (full Mark VIII charge) shows that, even at the highest power level (1250 MW), the margin from burnout is greater than 55% with normal flow and 40% with reduced flow.
Physical Description
3 p.
Notes
OSTI as DE94017283; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.