Cavitational flow has been known to exist in-rear crossheader ``Parker`` fittings at B, D, and F Reactors for the last five or six years. Calculations showing initiation of cavitational flow as a result of high flow rates in the present fittings were verified by experimental data in 1954. A study is currently being conducted to determine the required plant modifications to obtain flow increases on the order of fifty percent above existing flows. This study and the results of preliminary tests that show nominal flow increases may be obtained by reaming rear crossheader fittings has focused attention on the condition …
continued below
Publisher Info:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
Cavitational flow has been known to exist in-rear crossheader ``Parker`` fittings at B, D, and F Reactors for the last five or six years. Calculations showing initiation of cavitational flow as a result of high flow rates in the present fittings were verified by experimental data in 1954. A study is currently being conducted to determine the required plant modifications to obtain flow increases on the order of fifty percent above existing flows. This study and the results of preliminary tests that show nominal flow increases may be obtained by reaming rear crossheader fittings has focused attention on the condition of existing rear face piping. To obtain an estimate of the effect of cavitation in rear crossheader fittings resulting from past and current operating conditions, twenty one fittings were examined during the period October 6, 1959 to November 30, 1959. This document reports the inspection results.
Physical Description
9 p.
Notes
OSTI as DE94010612; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.