A study was made to determine operating temperatures of old pile HCR sheaths. The calculations were performed with the aid of a FORTRAN coded program for the IBM 7090. The difficulty of determining the correct value for the contact coefficient between the HCR and the graphite channel at any point in the channel length resulted in performing the calculations in a parametric style. The independent system parameters were varied during the calculations. These parameters are diametral spacing between the poison rings and the outer aluminum sheath, heat generation rate or reactor power level, the heat transfer contact coefficient between the …
continued below
Publisher Info:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
A study was made to determine operating temperatures of old pile HCR sheaths. The calculations were performed with the aid of a FORTRAN coded program for the IBM 7090. The difficulty of determining the correct value for the contact coefficient between the HCR and the graphite channel at any point in the channel length resulted in performing the calculations in a parametric style. The independent system parameters were varied during the calculations. These parameters are diametral spacing between the poison rings and the outer aluminum sheath, heat generation rate or reactor power level, the heat transfer contact coefficient between the rod and the graphite channel, and the cooling water temperature or cooling flow rate. For contact coefficients between 200 and 700 Btu/hr -- ft{sup 2} -- {degree}F and for diametral clearances around the poison of 5 mils to 20 mils, the maximum sheath temperature was calculated to vary between 350{degree}F and 650{degree}F. The dependence of sheath temperature upon the rod coolant temperature or coolant flow rate was found to be small enough to be neglected in the normal flow range of 12 gpm to 15 gpm. For a given increase of the average coolant temperature, the maximum sheath temperature increased about one half as much. Reversing the coolant flow in an HCR would not significantly reduce the maximum sheath temperature.
Physical Description
9 p.
Notes
OSTI as DE94010593; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.