The assumption of tube replacement losses can have a significant effect in the determination of optimum power levels and goal exposures. The tube replacement loss term in the reactor process optimization model is based on calculating the average projected tube replacement losses that will result from operation at given power and temperature conditions. Tube replacement losses associated with external corrosion, Van Stone flange failure, etc. (i.e., basically non-power level-temperature dependent) are assumed to be miscellaneous losses and are not included in the tube replacement term. Over a period of several years the experienced tube replacement losses (due to internal corrosion) …
continued below
Publisher Info:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The assumption of tube replacement losses can have a significant effect in the determination of optimum power levels and goal exposures. The tube replacement loss term in the reactor process optimization model is based on calculating the average projected tube replacement losses that will result from operation at given power and temperature conditions. Tube replacement losses associated with external corrosion, Van Stone flange failure, etc. (i.e., basically non-power level-temperature dependent) are assumed to be miscellaneous losses and are not included in the tube replacement term. Over a period of several years the experienced tube replacement losses (due to internal corrosion) should compare reasonably well with the losses predicted by the optimization model. Planned tube replacement project action which would require, in some cases, premature tube removal is a special situation which requires a modified approach to the prediction of tube replacement losses and to the optimization of reactor power levels prior to project action. A method has been developed for optimizing reactor power levels and goal exposures based on any assumed calendar date for major tube replacement project action. It is the purpose of this document to discuss the general application of this method in the optimization and illustrate the method by presenting specific application of the method to the K Reactors.
Physical Description
16 p.
Notes
OSTI as DE94012428; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.
Fuller, N. E. & Graves, S. M.Optimization of K Reactor power levels related to a zirconium tube replacement project,
report,
November 15, 1960;
Richland, Washington.
(https://digital.library.unt.edu/ark:/67531/metadc1314504/: