Loading, operating conditions, and water shutoff times for a charge of twelve 17-inch N inner fuel tubes or twelve 18-inch U-2 w/o Zr elements, PT-IP-536-A and PT-IP-536-A, Supplement B

PDF Version Also Available for Download.

Description

Production test IP-536-A authorizes the irradiation of N Reactor inner fuel tubes in KER-1 and KER-2. Supplement B, PT-IP-536-A, authorizes the irradiation of N Reactor inner fuel tubes prepared from a U-2 w/o Zr alloy. Both tests require that specific operating conditions and trip settings for particular loadings be approved by the managers of the Process and Reactor Development Sub-Section and the Process Technology Sub-Section prior to charging. The purpose of this document is to provide the process tube loading, high and low temperature operating limits, and water shutoff times for a charge of twelve 17.3-inch N inner fuel elements … continued below

Physical Description

4 p.

Creation Information

Kratzer, W. K. & Wise, M. J. January 28, 1963.

Context

This report is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by the UNT Libraries Government Documents Department to the UNT Digital Library, a digital repository hosted by the UNT Libraries. More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Sponsor

Publisher

  • Hanford Atomic Products Operation
    Publisher Info: General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
    Place of Publication: Richland, Washington

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Digital Library.

Description

Production test IP-536-A authorizes the irradiation of N Reactor inner fuel tubes in KER-1 and KER-2. Supplement B, PT-IP-536-A, authorizes the irradiation of N Reactor inner fuel tubes prepared from a U-2 w/o Zr alloy. Both tests require that specific operating conditions and trip settings for particular loadings be approved by the managers of the Process and Reactor Development Sub-Section and the Process Technology Sub-Section prior to charging. The purpose of this document is to provide the process tube loading, high and low temperature operating limits, and water shutoff times for a charge of twelve 17.3-inch N inner fuel elements or twelve 18.5-inch U-2 w/o Zr elements in KER-1 and KER-2. The operating conditions were prepared for the 17.3-inch elements and with the same downstream spacer column, are conservative for the slightly longer U-2 w/o Zr charge.

Physical Description

4 p.

Notes

OSTI as DE94010917; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov

Source

  • Other Information: DN: Declassified

Language

Item Type

Identifier

Unique identifying numbers for this report in the Digital Library or other systems.

Collections

This report is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • January 28, 1963

Added to The UNT Digital Library

  • Nov. 3, 2018, 11:47 a.m.

Description Last Updated

  • Nov. 20, 2018, 11:02 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 1
Total Uses: 4

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Kratzer, W. K. & Wise, M. J. Loading, operating conditions, and water shutoff times for a charge of twelve 17-inch N inner fuel tubes or twelve 18-inch U-2 w/o Zr elements, PT-IP-536-A and PT-IP-536-A, Supplement B, report, January 28, 1963; Richland, Washington. (https://digital.library.unt.edu/ark:/67531/metadc1314263/: accessed July 16, 2024), University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.

Back to Top of Screen