The reactivity control capacity of the N-reactor control systems has been calculated by methods which take into account the absorption of epithermal as well as thermo neutrons. Earlier calculations were made using a method which is satisfactory in control calculations for the existing Hanford reactors but which largely neglects the epithermal absorption. The new calculations were undertaken because of recent evidence that the epithermal absorption is more important to the NPR control strength and because of some concern regarding the margin between previously calculated control strength and anticipated control requirements. The calculational methods used in the present study and the …
continued below
Publisher Info:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Place of Publication:
Richland, Washington
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Descriptive information to help identify this report.
Follow the links below to find similar items on the Digital Library.
Description
The reactivity control capacity of the N-reactor control systems has been calculated by methods which take into account the absorption of epithermal as well as thermo neutrons. Earlier calculations were made using a method which is satisfactory in control calculations for the existing Hanford reactors but which largely neglects the epithermal absorption. The new calculations were undertaken because of recent evidence that the epithermal absorption is more important to the NPR control strength and because of some concern regarding the margin between previously calculated control strength and anticipated control requirements. The calculational methods used in the present study and the resulting calculated control capacities are reported in this document.
Physical Description
16 p.
Notes
OSTI as DE94010949; Paper copy available at OSTI: phone, 865-576-8401, or email, reports@adonis.osti.gov
This report is part of the following collection of related materials.
Office of Scientific & Technical Information Technical Reports
Reports, articles and other documents harvested from the Office of Scientific and Technical Information.
Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.