For an experiment to measure the magnetic moment of the Λ hyperon, it was necessary to extract the external beam of the Cosmotron with maximum efficiency and with minimum time duration. To accomplish this end, the standard external beam of the machine was supplemented with the Rapid Beam Ejector. It was found that, unfortunately, the ejection efficiency of the beam was less than normal when the RBE was used. Measurements of the ejection efficiency were made by irradiating polyethylene foils at the second focus of Beam 1 with 3 BeV protons. The external beam was tuned up and optimized in …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Brookhaven National Laboratory Report BNL-6678
Description
For an experiment to measure the magnetic moment of the Λ hyperon, it was necessary to extract the external beam of the Cosmotron with maximum efficiency and with minimum time duration. To accomplish this end, the standard external beam of the machine was supplemented with the Rapid Beam Ejector. It was found that, unfortunately, the ejection efficiency of the beam was less than normal when the RBE was used. Measurements of the ejection efficiency were made by irradiating polyethylene foils at the second focus of Beam 1 with 3 BeV protons. The external beam was tuned up and optimized in a standard manner. It was found that the ratio of the number of protons ejected with the RBE to the number ejected without the RBE was 0.3 in one run and 0.22 in another try. It was also observed that the RBE did not shift the position of the external proton beam focus to within ± 1/8 in.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.