The purpose of the survey was to determine the radiation level in the Turbine Generator Services Building, around the Fuel Handling Canal, in the limited access areas of the reactor plant containers and on the boiler container roofs during plant operation. The test was performed with the plant at approximately 100 per cent power with three loops (1A, 1B, and 1C) in service. The radiation levels of the areas surveyed with a few exceptions were essentially background (.03 MR/HR). These exceptions were the Auxiliary Chamber and the limited access areas between the containers. The highest radiation level obtained in the …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Atomic Energy Commission Report AECU-4513
Description
The purpose of the survey was to determine the radiation level in the Turbine Generator Services Building, around the Fuel Handling Canal, in the limited access areas of the reactor plant containers and on the boiler container roofs during plant operation. The test was performed with the plant at approximately 100 per cent power with three loops (1A, 1B, and 1C) in service. The radiation levels of the areas surveyed with a few exceptions were essentially background (.03 MR/HR). These exceptions were the Auxiliary Chamber and the limited access areas between the containers. The highest radiation level obtained in the survey was >2500 MR/HR at the reactor chamber walkway.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Ritz, William C.Periodic Radiation Survey. Section II. 4182-EFPH. Second Performance. Core I, Seed 1. Test Results DL-S-231 (T-612394),
report,
November 10, 1959;
Washington D.C..
(https://digital.library.unt.edu/ark:/67531/metadc1248625/: