Heat loss tests were conducted with six insulation configurations for application in the riser regenerator and auxiliary regenerator sections of the loop. Insulation consisting of ten laminations of 0.003 in. stainless steel shim stock spaced 1/8 inch apart produced a temperature drop across the 15/16 inch annulus of 1200 F with a heat loss of 1.04 KW per foot of 2 inch schedule 40 pipe. The curve of heat loss vs. temperature difference is presented which, with results of similar tests with a 1/4 inch annulus, will permit the evaluation of a heat balance and temperature profile for the entire …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Oak Ridge National Laboratory Report CF-59-8-57
Description
Heat loss tests were conducted with six insulation configurations for application in the riser regenerator and auxiliary regenerator sections of the loop. Insulation consisting of ten laminations of 0.003 in. stainless steel shim stock spaced 1/8 inch apart produced a temperature drop across the 15/16 inch annulus of 1200 F with a heat loss of 1.04 KW per foot of 2 inch schedule 40 pipe. The curve of heat loss vs. temperature difference is presented which, with results of similar tests with a 1/4 inch annulus, will permit the evaluation of a heat balance and temperature profile for the entire loop.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Knight, R. B. & Helms, R. E.Determination of Suitable Insulation for a 1-5/16" Helium Filled Annulus in the ORR Helium In-Pile Loop, Design No. 4,
report,
August 17, 1959;
Washington D.C..
(https://digital.library.unt.edu/ark:/67531/metadc1240920/:
accessed July 7, 2025),
University of North Texas Libraries, UNT Digital Library, https://digital.library.unt.edu;