A 15 MeV proton dianostic for DIII-D

PDF Version Also Available for Download.

Description

A 15 MeV proton diagnostic that is patterned after the ASDEX proton probe is presently being fabricated for the DIII-D tokamak. A bellows assembly inserts a silicon detector into the vacuum for plasma operation and retracts it for baking. The detector preamplifier is situated in a reentrant tube (at atmosphere) beside the detector; electrically, the whole assembly is referenced to vessel potential. Orbit calculations in realistic magnetic field geometries predict a proton detection efficiency of O(10{sup {minus}7}). The diagnostic will be used for burnup studies at high {beta} and particle transport studies in the H-mode. 25 refs., 4 figs.

Physical Description

11 pages

Creation Information

Duong, Hau & Heidbrink, W.W. (California Univ., Irvine, CA (USA)) October 1, 1990.

Context

This article is part of the collection entitled: Office of Scientific & Technical Information Technical Reports and was provided by UNT Libraries Government Documents Department to Digital Library, a digital repository hosted by the UNT Libraries. More information about this article can be viewed below.

Who

People and organizations associated with either the creation of this article or its content.

Publisher

  • General Atomic Company
    Publisher Info: General Atomics, San Diego, CA (USA)
    Place of Publication: San Diego, California

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this article. Follow the links below to find similar items on the Digital Library.

Description

A 15 MeV proton diagnostic that is patterned after the ASDEX proton probe is presently being fabricated for the DIII-D tokamak. A bellows assembly inserts a silicon detector into the vacuum for plasma operation and retracts it for baking. The detector preamplifier is situated in a reentrant tube (at atmosphere) beside the detector; electrically, the whole assembly is referenced to vessel potential. Orbit calculations in realistic magnetic field geometries predict a proton detection efficiency of O(10{sup {minus}7}). The diagnostic will be used for burnup studies at high {beta} and particle transport studies in the H-mode. 25 refs., 4 figs.

Physical Description

11 pages

Notes

NTIS, PC A03/MF A01; OSTI; INIS; GPO Dep.

Source

  • 8. topical conference on high-temperature plasma diagnostics, Hyannis, MA (USA), 6-10 May 1990

Language

Item Type

Identifier

Unique identifying numbers for this article in the Digital Library or other systems.

  • Other: DE91002717
  • Report No.: GA-A-20111
  • Report No.: CONF-900557--32
  • Grant Number: AC03-89ER51114
  • Office of Scientific & Technical Information Report Number: 6503677
  • Archival Resource Key: ark:/67531/metadc1204545

Collections

This article is part of the following collection of related materials.

Office of Scientific & Technical Information Technical Reports

Reports, articles and other documents harvested from the Office of Scientific and Technical Information.

Office of Scientific and Technical Information (OSTI) is the Department of Energy (DOE) office that collects, preserves, and disseminates DOE-sponsored research and development (R&D) results that are the outcomes of R&D projects or other funded activities at DOE labs and facilities nationwide and grantees at universities and other institutions.

What responsibilities do I have when using this article?

When

Dates and time periods associated with this article.

Creation Date

  • October 1, 1990

Added to The UNT Digital Library

  • July 5, 2018, 11:11 p.m.

Description Last Updated

  • April 26, 2019, 1:09 p.m.

Usage Statistics

When was this article last used?

Yesterday: 0
Past 30 days: 0
Total Uses: 1

Interact With This Article

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Duong, Hau & Heidbrink, W.W. (California Univ., Irvine, CA (USA)). A 15 MeV proton dianostic for DIII-D, article, October 1, 1990; San Diego, California. (https://digital.library.unt.edu/ark:/67531/metadc1204545/: accessed June 24, 2019), University of North Texas Libraries, Digital Library, https://digital.library.unt.edu; crediting UNT Libraries Government Documents Department.