Calculations indicate that it is impossible, even at high oxygen injection rates, to insure an excess of oxygen in the HRT fuel solution if the bubble letdown rate is more than 1 or 2 liters per minute. If, on the other hand, no bubbles are allowed to form, a reasonable excess oxygen concentration can be maintained with an oxygen injection rate which would not tax the capacity of the off-gas system. The xenon poison will be reduced to less than 2% by liquid letdown alone, and if an iodine absorption bed is installed below the catalytic recombiner, the xenon poison …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Oak Ridge National Laboratory Report CF-57-5-100
Description
Calculations indicate that it is impossible, even at high oxygen injection rates, to insure an excess of oxygen in the HRT fuel solution if the bubble letdown rate is more than 1 or 2 liters per minute. If, on the other hand, no bubbles are allowed to form, a reasonable excess oxygen concentration can be maintained with an oxygen injection rate which would not tax the capacity of the off-gas system. The xenon poison will be reduced to less than 2% by liquid letdown alone, and if an iodine absorption bed is installed below the catalytic recombiner, the xenon poison should be less than 1% without any bubble letdown. Therefore, it is recommended that sufficient copper be added to prevent the formation of gas bubbles and that the oxygen injection rate be limited to a value which would permit adequate holdup times in the present charcoal adsorption beds, assuming this quantity is sufficient to meet corrosion requirements.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Haubenreich, P. N.Effects of Letdown Rates and Oxygen Injection Rates on Xenon Poison Level and Excess Oxygen Concentration in the HRT,