After several failures had occurred in the HRT leak detector system, several lengths of this tubing were removed for metallurgical examination. The tubing was of type 304 stainless steel and was 1/4" in diameter with a 0.065 wall. The tubing had been purchased as three different lots, the first in 45 ft. lengths and the other two as standards lengths. Tubing from the first lot was used primarily for the shield penetration and, therefore, sections of it are present in all lines of the system. It appears that chloride contamination entered the system in a portion of the first lot …
continued below
We've identified this
report
as a primary source within our collections. Researchers, educators, and students may find this report useful in their work.
Provided By
UNT Libraries Government Documents Department
Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.
Added Title:
Oak Ridge National Laboratory Report CF-57-1-109
Description
After several failures had occurred in the HRT leak detector system, several lengths of this tubing were removed for metallurgical examination. The tubing was of type 304 stainless steel and was 1/4" in diameter with a 0.065 wall. The tubing had been purchased as three different lots, the first in 45 ft. lengths and the other two as standards lengths. Tubing from the first lot was used primarily for the shield penetration and, therefore, sections of it are present in all lines of the system. It appears that chloride contamination entered the system in a portion of the first lot of tubing used for the shield penetration. The exact source of the chloride cannot be determined, but after considering the results and visiting the manufacturer's plant, it appears most likely the contamination was during the manufacturing process.
This report is part of the following collections of related materials.
TRAIL Microcard Collection
Imaged from microcard, these technical reports describe research performed for U.S. government agencies from the 1930s to the 1960s. The reports were provided by the Technical Report Archive and Image Library (TRAIL).
The Technical Report Archive & Image Library (TRAIL) identifies, acquires, catalogs, digitizes and provides unrestricted access to U.S. government agency technical reports. The mission of TRAIL is to ensure preservation, discoverability, and persistent open access to government technical publications regardless of form or format.
Adamson, G. M; Hammond, T. M.; Kegley, T. M. & White, J. K.Metallurgical Examination of HRT Leak Detector Tubing and Flanges,